Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
www.powersolve.co.uk
High Density DC-DC Modules
Output Voltage and Current Ratings
Pin Function
1 +Vin
2 ON/OFF
3 CASE
4 -Vin
5 -Vout
6 -Sense
7 Trim
8 +Sense
9 +Vout
Pin Connection
All dimensions in inches (mm)
Tolerances Inches x.xx ±0.02 x.xxx ±0.010
Millimeters x.x ±0.5 x.xx ±0.25
MODEL INPUT OUTPUT OUTPUT INPUT CURRENT % EFF. CAPACITOR
VOLTAGE VOLTAGE CURRENT NO LOAD FULL LOAD LOAD max.
PS200W-24S3V3 10-36VDC 3.3VDC 50A 130mA 7.90A 87 10000µF
PS200W-24S05 10-36VDC 5VDC 40A 150mA 9.58A 87 10000µF
PS200W-24S12 10-36VDC 12VDC 16.7A 50mA 9.71A 86 2200µF
PS200W-24S15 10-36VDC 15VDC 13.3A 50mA 9.56A 87 2200µF
PS200W-24S24 10-36VDC 24VDC 8.3A 45mA 9.54A 87 2200µF
PS200W-24S48 10-36VDC 48VDC 4.2A 60mA 9.77A 86 2200µF*
PS200W-48S3V3 18-75VDC 3.3VDC 40A 80mA 3.13A 88 10000µF
PS200W-48S05 18-75VDC 5VDC 40A 80mA 4.68A 89 10000µF
PS200W-48S12 18-75VDC 12VDC 16.7A 60mA 4.74A 88 2200µF
PS200W-48S15 18-75VDC 15VDC 13.3A 60mA 4.72A 88 2200µF
PS200W-48S24 18-75VDC 24VDC 8.3A 60mA 4.72A 88 2200µF
PS200W-48S48 18-75VDC 48VDC 4.2A 50mA 4.83A 87 2200µF*
NOTES:
Nominal Input Voltage 24VDC or 48VDC
The output terminal of 48Vout models requires a minimum capacitor of 47µF to maintain specified regulation.
Mechanical and Connection Details
Remote ON/OFF Control
The PS200W Series allows the user to switch the module on and off electronically with the remote on/off feature.
The PS200W Series are available with “positive logic” or “negative logic” (option).
Logic Table
Logic State
(Pin 2)
Negative
Logic
Positive
Logic
Logic low-
Switch closed
Module on Module off
Logic high-
Switch open
Module off Module on
External Output Trim
The output can be trimmed externally (±10%) using a fixed resistor or
a trimpot as shown.
Output Noise
The output noise is measured with a 10µF tantalum and a 1.0µF
ceramic capacitor across the output.