Line regulation
±0.5% max.
Load regulation:
–Single output models: ±0.5% max.
–Dual output models: ±0.5% max.
Ripple & Noise: <50 mVpk-pk (20 MHz BW)
Conducted EMI: EN 55022, class A and FCC, level A (internal filter)
Short circuit protection: continuous, automatic recovery
Efficiency: 83% typ. 3.3 VDC models
Operating temperature range: –40°C … +85°C above 60°C derating 2%/°C
I/O isolation voltage: 1500 VDC
Safety standards: cUL/UL 60950, IEC/EN 60950
Case: metal, 6-side shielded with insulated baseplate
Option: shutdown input for low input current (10 mA) in standby operation
www.powersolve.co.uk
Powersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: [email protected]
Order Code Input voltage Output voltage Output current
max.
TEN 12-2410 3.3 VDC 2400 mA
TEN 12-2411 5 VDC 2000 mA
TEN 12-2412 12 VDC 1000 mA
TEN 12-2413 9 – 36 VDC 15 VDC 800 mA
TEN 12-2421 ±5 VDC ±1000 mA
TEN 12-2422 ±12 VDC ±500 mA
TEN 12-2423 ±15 VDC ±400 mA
TEN 12-4810 3.3 VDC 2400 mA
TEN 12-4811 5 VDC 2000 mA
TEN 12-4812 12 VDC 1000 mA
TEN 12-4813 18 – 75 VDC 15 VDC 800 mA
TEN 12-4821 ±5 VDC ±1000 mA
TEN 12-4822 ±12 VDC ±500 mA
TEN 12-4823 ±15 VDC ±400 mA
= 51x25x10 mm Metal Package
= Ultrawide 4:1 Input Range
= Very high Efficiency up to 84%
= Operating Temperature Range –40°C to +85°C
= I/O Isolation 1500 VDC
= Short Circuit Protection
=
Input Filter to meet EN 55022, Class A
= Remote On/Off (option)
= Industry Standard Pinout
DC/DC Converters
TEN 12WI Series, 12 Watt
Models
Pin Single Output Dual Output
1 + Vin (Vcc) + Vin (Vcc)
2
– Vin (GND) – Vin (GND)
3
+ V
out
+ V
out
4 No pin Common
5
– V
out
– V
out
6
Remote On/Of
f
Remote On/Of
f
(option) (option)
Pin-Out
20.32
10.26
50.8
25.4
2
1
54
3
Bottom view
10.16
15.2
2.5
Insulated Baseplate
(1.0)
(0.1)
(0.4)
(0.24)
(2.0)
(0.8)
(0.6)
(0.4)
7.62
(0.3)
6
7.62
(0.3)
10.16
(0.4)
5.08 (0.2)
() = Inches Pin
Ø
1.0 mm (0.04)