www.powersolve.co.uk
Powe rsolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England
Desk Top Power Supplies
MODEL OUTPUT VOLTAGE MAX LOAD MIN LOAD RIPPLE & NOISE VOLTAGE LINE LOAD
ACCURACY REGULATION REGULATION
PS100A120 12V 8.33 A 0A 1% ±2% ±1% ±4%
PS100A150 15V 6.67 A 0A 1% ±2% ±1% ±4%
PS100A180 18V 5.56 A 0A 1% ±2% ±1% ±2%
PS100A190 19V 5.21 A 0A 1% ±2% ±1% ±2%
PS100A240 24V 4.17 A 0A 1% ±2% ±1% ±2%
PS100A280 28V 3.54 A 0A 1% ±2% ±1% ±2%
PS100A290 29V 3.41 A 0A 1% ±2% ±1% ±2%
PS100A300 30V 3.30 A 0A 1% ±2% ±1% ±2%
PS100A360 36V 2.78 A 0A 1% ±2% ±1% ±2%
PS100A480 48V 2.08 A 0A 1% ±2% ±1% ±2%
Note:
1. Voltage accuracy is set at 60% load.
2. Add a 0.1mF ceramic capacitor and a 10mF E.L. capacitor to output for Ripple & Noise measurement @20MHz BW.
3. Line regulation measured from 100Vac to 240Vac, full load.
4. Load regulation measured from 60% to full load and from 60% to 20% load (60% +/- 40% load)
5. Cable length limit for PS100A120/150: 1200mm (max)
Cable length for PS100A180/190/240/480: 1800mm (max)
Stock items fitted with 2.5 x 5.5 x 11mm barrel connector, centre positive
Options: Optional output connector - consult sales office for details
Kommentare zu diesen Handbüchern