Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
www.powersolve.co.uk
AC-DC Converters
PPS120P Series
90/120 Watts
Single, Dual, Triple & Quad Outputs
Features
• Active power factor correction
• IEC EN61000-3-2 (D) compliance
• Universal input
• Built-in EMI filter
• UL/cUL, TUV safety approved
• Optional cover
INPUT
Input range 90~264 VAC, universal
Frequency 47~63Hz
Inrush current 38A typical, Cold start @ 25°C, 115 VAC
Efficiency 65%~85% typical at full load
EMI filter FCC part 15 Class B, CISPR 22/EN55022 Class B
Power factor >0.97@115 VAC
>0.95@230 VAC Typ.
OUTPUT
Max. power 90W convection, 120W with 30CFM forced air
Line Regulation ±0.5%
Load Regulation
Main Output +3%, Aux. Outputs +5% T
yp.
Cross Regulation Main Output +5%, Aux. Outputs +10% Typ.
Hold-up Time 16mS Typ. at full load, 115 VAC
Noise & Ripple
1% T
yp.
Over Voltage Protection latch-off
Overload Pr
otection
auto-r
ecovery
Short Circuit Protection auto-recovery
Output adjust output 1 ±10%
ENVIRONMENTAL
Operating temperatur
e
0
°
C to 50
°C ambient, derate each output at 2.5% per degree from 50°C to 70°C
Storage temperature -40°C to 85°C
Electromagnetic susceptibility meet IEC 801-2,-3,-4,-5 Level 3
Humidity
Operating, non-condensing 5% to 95%
Vibration 10 to 55Hz at 1G, 3 minutes period, 30 minutes along X,Y and Z axis
T
emperatur
e coefficient +0.05% per degree C
MTBF demonstration >100,000 hours at 25°C
Safety approvals UL1950/cUL, TUV EN60950
Electrical Specification
Kommentare zu diesen Handbüchern