Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
p.2/2 03.12B
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
85..132Vac / 184..265Vac , 47…63Hz , 110…375Vdc
115Vac <2.2A 230Vac <1.1A
230Vac 20MHz
1.Vout+(T= DIN Rail ; W= wall mount) Exa
Terminal Connects:
1 = L
SK1 2 = N
3 = GND
1 = DC +
2 = DC +
SK2 3 = DC -
4 = DC -
5 = relay
(not 72V &
6 = relay
110V)
Screw terminal order codes:
(each package = 10 pcs )
for SK1 1pc (3520038)
SK2 2-3pcs (3520037)
Art.No.: 3520038 (3 pins)
Art.No.: 3520037 (2 pins)
EN55022 class B / EN61000
Air & Surface Leakage Paths
DC Fail Relay (galv. Insulated)
normally closed contact
Conception:
The HSE power supply series realizes very high power efficiency in a
space-saving housing. This design enables Green Power applications
and allows free air convection. Latest generation electrical devices
relate to the high reliability of all Camtec products. The Camtec
philosophy is, to employ 125°C low ESR ultra long life capacitors
where expedient to achieve a superior lifetime of our products. The
used screw terminal plugs allow easy to wire, smooth service and
protect you from mix-up the input with the output signals.
Parallel Operation Mode:
Parallel operation of equal HSE-Power-Supplies provides you
a higher output power. Make sure that the DC voltages differ
at only ±1% and that DC cables are of equal length.
Series Operation Mode:
To raise the output voltage you can drive equal HSE power
supplies in series, too.
Kommentare zu diesen Handbüchern