Features
• Universal input range 90-264Vac
• 2” x 4” (50.8 x 101.6mm) size
• Industry standard pin outs
• Efficiency to 83%
• Meets CISPR/FCC Class B, conducted
• Continuous short circuit protection
INPUT
Input Voltage Range 90 - 264Vac
Frequency 47 - 63Hz
Inrush Current 50A max. @ 240Vac
Cold start @ 25°C
Conducted EMI CISPR/FCC Class B
Isolation - Input/Output 4242VDC
Leakage Current 3.5mA max.
OUTPUT
Hold-up Time 8mS typ. @ 115Vac
Short Circuit Protection Continuous
Temperature Coefficient ±0.05% / °C
Over voltage Protection Auto recovery
ENVIRONMENTAL
Operating Temperature Range 0°C to 50°C
Storage Temperature Range -20°C to +85°C
Cooling Natural convection
Safety Approvals cUL/UL 60950, TUV EN60950
GENERAL
Dimensions 101.6 x 50.8 x 32.0 mm
4.0 x 2.0 x 1.26 inches
Weight 170g
Electrical Specification
Typical at 25°C, nominal line and 75% load unless otherwise stated.
Output Voltage and Current Ratings
MODEL OUTPUT OUTPUT CURRENT RIPPLE VOLTAGE LINE LOAD OUTPUT % EFF.
VOLTAGE Min. Rated Max. (mV pk-pk) ACCURACY REG. REG. POWER max.
V1 = 5V 0A 4.0A 5.0A 50mV ±2% ±1% ±4%
CFM60T-01 V2 = 12V 0A 3.0A 3.7A 120mV ±5% ±1% ±3% 62W 83%
V3 = -12V 0A 0.5A 0.65A 120mV ±5% ±1% ±5%
V1 = 5V 0A 4.0A 5.0A 50mV ±2% ±1% ±4%
CFM60T-02 V2 = 15V 0A 2.5A 3.1A 150mV ±4% ±1% ±3% 62W 83%
V3 = -15V 0A 0.3A 0.5A 150mV ±5% ±1% ±5%
V1 = 5V 0A 4.0A 5.0A 50mV ±2% ±1% ±4%
CFM60T-03 V2 = 24V 0A 1.5A 1.8A 240mV ±3% ±1% ±3% 62W 83%
V3 = -12V 0A 0.5A 0.6A 120mV ±5% ±1% ±5%
V1 = 3.3V 0A 6.0A 7.5A 50mV ±4% ±1% ±5%
CFM60T-04 V2 = 5V 0A 3.0A 3.7A 50mV ±5% ±1% ±4% 40.8W 78%
V3 = -12V 0A 0.5A 0.65A 120mV ±5% ±2% ±5%
www.powersolve.co.uk
NOTE:
1. Voltage accuracy is measured at 60% rated load.
2. Output noise and ripple measured with 10µF tantalum & 0.1µF ceramic capacitors across output.
3. Line regulation is measured from 103Vac - 127Vac & 207Vac - 253Vac at rated load.
4. Load regulation is defined by changing Output1 load from 20-100% of rated with other loads at 60% of rated.