January 2010 Page 1 - 2
PSC-CP
Output voltage and current setting and read back
• 14 bit resolution for setting the output voltage and current
• 14 bit resolution for read back (monitoring) of the output voltage and current
• Tc typical 15 ppm/K
• Full scale accuracy < 0.1 %
• Factory offset and full scale calibration in combination with power supply
Status monitoring
The following power supply statuses can be read: ACF, DCF, LIM, OT, PSOL and CC
• ACF = AC Fail • OT = Overtemperature
• DCF = DC Fail • PSOL = Power Sink Overload
• LIM = Voltage and current limit reached • CC = Constant Current mode
CANopen features
• SYNC Object • Expedited and Nonexpedited SDO transfer
• Emergency object • Node address range 1 - 127
• Node guarding • Baud rate setting range 10 kbit/s - 1 Mbit/s
• Heartbeat
PROFIBUS features
• Slave in a PROFIBUS-DP network
•
DP
-V0 standard according to IEC 61784 Ed. 1:2002 CPF 3/1
• PROFIBUS protocol according IEC 61158
• Slave address range 1 - 127
ES150 - Se ries Op tion P279 PROFIBUS An a log pro gram ming con nec tor removed
ES150 - Se ries Op tion P280 CANopen Analog pro gram ming con nec tor removed
ES 030-10 Op tion P281 PROFIBUS An a log pro gram ming con nec tor removed
ES 030-10 Op tion P282 CANopen An a log pro gram ming con nec tor removed
SM 800 - Se ries Op tion P271 FROFIBUS An a log pro gram ming con nec tor still available
SM 800 - Se ries Op tion P272 CANopen An a log pro gram ming con nec tor still available
SM 1500 - Se ries Op tion P273 PROFIBUS An a log pro gram ming con nec tor still available
SM 1500 - Se ries Op tion P274 CANopen An a log pro gram ming con nec tor still available
SM 3000 - Se ries Op tion P275 PROFIBUS An a log pro gram ming con nec tor removed
SM 3000 - Se ries Op tion P276 CANopen An a log pro gram ming con nec tor removed
SM 6000 - Se ries Op tion P277 PROFIBUS An a log pro gram ming con nec tor still avail able **
SM 6000 - Se ries Op tion P278 CANopen An a log pro gram ming con nec tor still avail able **
Mod els Op tion code In ter face Com ments
Controls
The power supply can be set in RSD mode.
• RSD = Remote Shut Down: shuts down the output of the power supply.
**Note : Ex cept on SM 600-10 and SM 300-20